{"id":101,"date":"2020-05-08T01:41:45","date_gmt":"2020-05-08T04:41:45","guid":{"rendered":"http:\/\/www.quilombodigital.org\/wordpress\/?p=101"},"modified":"2020-05-09T12:52:29","modified_gmt":"2020-05-09T15:52:29","slug":"conversao-de-cpap-em-ventilador-de-emergencia","status":"publish","type":"post","link":"https:\/\/www.quilombodigital.org\/wordpress\/?p=101","title":{"rendered":"Convers\u00e3o de CPAP em Ventilador de Emerg\u00eancia"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img width=\"1000\" height=\"750\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4637.jpg\" alt=\"\" class=\"wp-image-114\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4637.jpg 1000w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4637-300x225.jpg 300w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4637-768x576.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p class=\"has-text-color has-large-font-size has-vivid-red-color\"><strong>AVISO OBRIGAT\u00d3RIO<\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-background has-medium-font-size has-vivid-red-color has-very-light-gray-background-color\"><strong>Esta modifica\u00e7\u00e3o de equipamento \u00e9 um apenas uma prova de conceito, n\u00e3o deve ser utilizado para o tratamento de COVID ou qualquer outra doen\u00e7a respirat\u00f3ria. Seu uso n\u00e3o foi devidamente comprovado por m\u00e9dicos e especialistas<\/strong>.<\/p>\n\n\n\n<p class=\"has-large-font-size\"><strong>Introdu\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<p>Como podemos observar na m\u00eddia, os ventiladores s\u00e3o um recurso escasso nos hospitais. V\u00e1rios projetos visam ajudar com isso, utilizando ventiladores de emerg\u00eancia, como:<\/p>\n\n\n\n<p><strong>USP <\/strong>&#8211; <a href=\"https:\/\/jornal.usp.br\/ciencias\/ventilador-pulmonar-emergencial-criado-por-engenheiros-da-usp-e-aprovado-nos-testes\/\">https:\/\/jornal.usp.br\/ciencias\/ventilador-pulmonar-emergencial-criado-por-engenheiros-da-usp-e-aprovado-nos-testes\/<\/a><\/p>\n\n\n\n<p><strong>Mau\u00e1 <\/strong>&#8211; <a href=\"https:\/\/www.facebook.com\/watch\/?v=230305984754118\">https:\/\/www.facebook.com\/watch\/?v=230305984754118<\/a><\/p>\n\n\n\n<p><strong>MIT <\/strong>&#8211; <a href=\"https:\/\/www.techtudo.com.br\/noticias\/2020\/03\/mit-desenvolve-ventilador-barato-para-ajudar-no-tratamento-da-covid-19.ghtml\">https:\/\/www.techtudo.com.br\/noticias\/2020\/03\/mit-desenvolve-ventilador-barato-para-ajudar-no-tratamento-da-covid-19.ghtml<\/a><\/p>\n\n\n\n<p><strong>Inspirado por estes projetos eu procurei uma maneira de ajudar, e encontrei o projeto AIRBREAK (<a href=\"https:\/\/airbreak.dev\/\">https:\/\/airbreak.dev\/<\/a>) e resolvi fazer um post descrevendo os passos para a convers\u00e3o de um CPAP em um ventilador de emerg\u00eancia.<\/strong><\/p>\n\n\n\n<p>Para os que n\u00e3o conhecem o CPAP \u00e9 um equipamento utilizado no tratamento de apn\u00e9ia e disturbios do sono. CPAP \u00e9 a abrevia\u00e7\u00e3o de &#8220;<a href=\"https:\/\/en.wikipedia.org\/wiki\/Positive_airway_pressure\">Continuos Positive Airway Pressure<\/a>&#8220;, simplificando, \u00e9 um equipamento que gera um fluxo constante de ar.<\/p>\n\n\n\n<p>Um ventilador \u00e9 um equipamento muito mais complexo, com sensores e modos de opera\u00e7\u00e3o bem distintos, e o pessoal da Airbreak descobriu que uma marca de CPAPs (Autosense 10) poderia ser utilizada para isto. Embora de f\u00e1brica ele venha configurado para fornecer press\u00e3o de no m\u00e1ximo 20cm\/H2O, ele consegue fornecer de 4 a 30cm\/H2O, e possui todos os sensores e modos de opera\u00e7\u00e3o necess\u00e1rios para funcionar como ventilador de emerg\u00eancia.<\/p>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio wp-embed-aspect-4-3\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"cpap2\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/ywnNMCIn77s?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p>Ent\u00e3o voc\u00ea me pergunta, se ele pode ser utilizado no in\u00edcio da falta de ar, porqu\u00ea ele n\u00e3o \u00e9 utilizado? O motivo principal \u00e9 que diferente do ventilador com entubamento (invasivo), ele n\u00e3o \u00e9 um sistema fechado.<br>A respira\u00e7\u00e3o escapa pelas laterais da m\u00e1scara, portanto ele pode proliferar o v\u00edrus no ambiente, o que \u00e9 um problema grande para hospitais onde h\u00e1 outros pacientes com diferentes doen\u00e7as. Nos Estados Unidos, eles chegaram \u00e0 conclus\u00e3o que isso pode ser controlado com as devidas medidas em ambientes monitorados e com pacientes que j\u00e1 possuem covid, e com equipamentos e filtros que diminuem essa exposi\u00e7\u00e3o aos funcion\u00e1rios. (<a href=\"https:\/\/www.businessinsider.com\/nyc-hospital-mount-sinai-turns-sleep-apnea-machines-into-ventilators-2020-4\">https:\/\/www.businessinsider.com\/nyc-hospital-mount-sinai-turns-sleep-apnea-machines-into-ventilators-2020-4<\/a>)<\/p>\n\n\n\n<p>O hospital Mount Sinai de Nova Iorque desenvolveu um protocolo para a utiliza\u00e7\u00e3o deste tipo de equipamento no tratamento de covid, contendo quais as modifica\u00e7\u00f5es que devem ser feitas e quais as a\u00e7\u00f5es a serem feitas pelos funcion\u00e1rios, assim como as configura\u00e7\u00f5es a serem utilizadas:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img width=\"710\" height=\"324\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/image-1.png\" alt=\"\" class=\"wp-image-132\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/image-1.png 710w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/image-1-300x137.png 300w\" sizes=\"(max-width: 710px) 100vw, 710px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/rtsleepworld.com\/wp-content\/uploads\/2020\/04\/Mt-Sinai-bipap-protocol.pdf\"><strong>https:\/\/rtsleepworld.com\/wp-content\/uploads\/2020\/04\/Mt-Sinai-bipap-protocol.pdf<\/strong><\/a><\/p>\n\n\n\n<p class=\"has-large-font-size\"><strong>Instru\u00e7\u00f5es para convers\u00e3o<\/strong><\/p>\n\n\n\n<p>O ideal \u00e9 que a pessoa siga os passos do website <strong>AIRBREAK<\/strong>, mas aqui eu vou colocar alguns videos e instru\u00e7\u00f5es com dificuldades que encontrei no caminho.<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Prepara\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<ul><li>Retirar a capa frontal<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"capa\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/07sxTi7O_Sk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<ul><li>Retirar 4 parafusos que prendem a tampa e remover a tampa<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio wp-embed-aspect-16-9\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"parafuso\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/3O4ZMvF0_AA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<ul><li>Retirar capa externa<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"capaexterna\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/7NdZVxx3AOg?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<ul><li>Retirar Dial e tampa<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio wp-embed-aspect-16-9\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"dialetampa\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/3qGnoyuQNmE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<ul><li>Desconectar os conectores do humidificador e acesso celular<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img width=\"1024\" height=\"768\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/heatbed-radio-1024x768.jpg\" alt=\"\" class=\"wp-image-106\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/heatbed-radio-1024x768.jpg 1024w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/heatbed-radio-300x225.jpg 300w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/heatbed-radio-768x576.jpg 768w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/heatbed-radio-1536x1152.jpg 1536w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/heatbed-radio-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Conex\u00e3o JTAG<\/strong><\/p>\n\n\n\n<p>Agora vem a parte um pouco mais complicada. Este CPAP possui somente os pads para um conector pequeno e bem peculiar. Eu procurei o cabo espec\u00edfico (<a href=\"https:\/\/www.digikey.com\/product-detail\/en\/TC2050-IDC\/TC2050-IDC-ND\/2605366\"><\/a><a href=\"https:\/\/www.digikey.com\/product-detail\/en\/tag-connect-llc\/TC2050-IDC-NL\/TC2050-IDC-NL-ND\/2605367\">TC2050-ICD-NL<\/a>) mas ele n\u00e3o existe no Brasil, e l\u00e1 fora custa 39 d\u00f3lares!. Eu resolvi soldar os fios diretamente nos pads, pois v\u00ed que o pessoal l\u00e1 fora tamb\u00e9m estava fazendo isso, mas eu devo dar um aviso importante: Os pads s\u00e3o <strong>MUITO <\/strong>pequenos e sens\u00edveis. Mantenha o CPAP numa base firme, pois eu o derrubei, os fios bateram e arrancaram dois pads, quase colocando tudo a perder. Depois do susto, respirei com calma, estanhei um fio bem fino de cobre e soldei numa via, restaurando a conex\u00e3o, portanto tenha cuidado!<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>PINAGEM DA PLACA<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img width=\"733\" height=\"431\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/image.png\" alt=\"\" class=\"wp-image-108\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/image.png 733w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/image-300x176.png 300w\" sizes=\"(max-width: 733px) 100vw, 733px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"pads\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Pzf0_kgYPIw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img width=\"1024\" height=\"728\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4601-1024x728.jpg\" alt=\"\" class=\"wp-image-107\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4601-1024x728.jpg 1024w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4601-300x213.jpg 300w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4601-768x546.jpg 768w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4601-1536x1092.jpg 1536w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/IMG_4601.jpg 1599w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Como eu utilizei um clone do STLINK v2 para fazer a grava\u00e7\u00e3o do firmware, s\u00e3o utilizados apenas 4 pinos. Os pinos utilizados s\u00e3o o 2 (STM32_SWDIO), 4 (STM32_SWCLK), 5 (GND) e o 10 (STM32_NRST).<\/strong> Se voc\u00ea possuir o stlink original , pode utilizar o quinto pino, 1 (STM32_VDD) no 3.3v, mas <strong>somente <\/strong>se for original, pois poder\u00e1 queimar algo. Na d\u00favida, n\u00e3o conecte.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img width=\"1000\" height=\"734\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/stlink.jpg\" alt=\"\" class=\"wp-image-111\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/stlink.jpg 1000w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/stlink-300x220.jpg 300w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/stlink-768x564.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p>Por fim \u00e9 uma boa id\u00e9ia retirar o <strong>SDCARD <\/strong>que vem inserido no equipamento. Durante os meus testes eu tive problemas com o aparelho reiniciando o tempo inteiro, e no github me aconselharam retirar o sdcard e funcionou. Eu tamb\u00e9m mudei a linguagem de portugu\u00eas para ingl\u00eas e resetei para os valores de f\u00e1brica.<\/p>\n\n\n\n<p class=\"has-large-font-size\"><strong>Software e programa\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<p>Eu n\u00e3o preciso nem dizer que voc\u00ea <strong>DEVE <\/strong>seguir os passos do site do <strong>AIRBREAK <\/strong>(<a href=\"https:\/\/airbreak.dev\/\">https:\/\/airbreak.dev<\/a>), mas vou deixar aqui registrado algumas observa\u00e7\u00f5es:<\/p>\n\n\n\n<ul><li>Antes de come\u00e7ar voc\u00ea deve verificar qual a vers\u00e3o do firmware. O airbreak atualmente suporta a vers\u00e3o 306 e a 401. Se o seu equipamento for de uma vers\u00e3o diferente, ser\u00e1 mais dif\u00edcil, voc\u00ea deve entrar em contato com eles pelo github e pedir ajuda, mas os caras s\u00e3o super sol\u00edcitos e ajudam bastante. Para ver o n\u00famero da vers\u00e3o voc\u00ea deve pressionar o bot\u00e3o inferior e o bot\u00e3o do Dial por 3 segundos. Isso faz aparecer o menu cl\u00ednico, que possui mais informa\u00e7\u00f5es.<\/li><li>Utilizei o ubuntu 18.04 atualizado<\/li><li>Clonar o reposit\u00f3rio do github, e \u00e9 sempre bom dar uma olhada na lista de issues do github, h\u00e1 muitas informa\u00e7\u00f5es valiosas l\u00e1.<\/li><li>No que se refere \u00e0 depend\u00eancias como o openocd e o toolchain arm, os pacotes padr\u00e3o do ubuntu n\u00e3o funcionam, tem que compilar e instalar do c\u00f3digo fonte. Prestar aten\u00e7\u00e3o nas depend\u00eancias necess\u00e1rias do stlink para o openocd, vis\u00edveis ao se dar configure.<\/li><li>Pr\u00f3ximos passos est\u00e3o descritos aqui: <a href=\"https:\/\/airbreak.dev\/firmware\/\">https:\/\/airbreak.dev\/firmware\/<\/a><\/li><li>Testar a conex\u00e3o do stlink com o openocd.<\/li><li>Com a conex\u00e3o funcionando, fazer o dump do firmware original \u00e9 trivial, e qualquer problema tudo pode ser facilmente revertido.<\/li><li>Gerar o checksum do bin\u00e1rio (sha256sum).<\/li><li>Se voc\u00ea rodar o script patch-airsense e o checksum n\u00e3o bater, ent\u00e3o voc\u00ea pode modificar o script para aceitar o checksum. Note que essa modifica\u00e7\u00e3o deve acompanhar a l\u00f3gica da vers\u00e3o de firmware (306 ou 401)<\/li><li>Como a minha vers\u00e3o de script era a 306, e a vers\u00e3o oficial \u00e9 a 401, ao conversar com um dos desenvolvedores, David Blunk, ele me aconselhou utilizar este patch (<a href=\"https:\/\/github.com\/dblunk88\/airbreak\/blob\/master\/patch-airsense\">https:\/\/github.com\/dblunk88\/airbreak\/blob\/master\/patch-airsense<\/a>)<\/li><li>Executar o script de patch<\/li><li>Gravar o novo firmware no equipamento tamb\u00e9m foi trivial.<\/li><li>Testar.<\/li><\/ul>\n\n\n\n<p class=\"has-large-font-size\"><strong>Testes<\/strong><\/p>\n\n\n\n<p>Para testar, entrar no <strong>menu cl\u00ednico<\/strong> e escolher o modo <strong>iVaps<\/strong>. Colocar a m\u00e1scara e perceber que no momento que ocorre uma tentativa de respira\u00e7\u00e3o ele empurra mais ar. Outro modo a ser utilizado \u00e9 o <strong>ST <\/strong>(Bipap-ST).<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img src=\"https:\/\/airbreak.dev\/images\/airsense-ivaps.jpg\" alt=\"iVAPS mode unlocked\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-container\"><iframe title=\"hacked\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/z4gIDG5fsaY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p>Eu n\u00e3o sei como \u00e9 a m\u00e1scara que vem com ele, eu utilizei uma m\u00e1scara facial boa que comprei \u00e0 parte, s\u00f3 sei que \u00e9 importante uma m\u00e1scara com boa veda\u00e7\u00e3o e adequada ao formato do seu rosto. Costuma-se medir a dist\u00e2ncia entre o canal lacrimal do olho e o meio do queixo (1cm abaixo do l\u00e1bio) para escolher a m\u00e1scara.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img width=\"872\" height=\"1024\" src=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/1DA28663-AB26-4EC2-BE21-8BAC0D9CDB7B-872x1024.jpg\" alt=\"\" class=\"wp-image-112\" srcset=\"https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/1DA28663-AB26-4EC2-BE21-8BAC0D9CDB7B-872x1024.jpg 872w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/1DA28663-AB26-4EC2-BE21-8BAC0D9CDB7B-256x300.jpg 256w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/1DA28663-AB26-4EC2-BE21-8BAC0D9CDB7B-768x902.jpg 768w, https:\/\/www.quilombodigital.org\/wordpress\/wp-content\/uploads\/2020\/05\/1DA28663-AB26-4EC2-BE21-8BAC0D9CDB7B.jpg 1000w\" sizes=\"(max-width: 872px) 100vw, 872px\" \/><\/figure>\n\n\n\n<p>Lembrando que voc\u00ea pode a qualquer momento restaurar o firmware e voltar o equipamento exatamente ao mesmo ponto que estava.<\/p>\n\n\n\n<p><strong>Voc\u00ea pode conferir a an\u00e1lise de performance do aparelho que o pessoal do AIRBREAK fez aqui: <a href=\"https:\/\/airbreak.dev\/evaluation\/\">https:\/\/airbreak.dev\/evaluation\/<\/a><\/strong><\/p>\n\n\n\n<p class=\"has-large-font-size\"><strong>Considera\u00e7\u00f5es Finais<\/strong><\/p>\n\n\n\n<p>Voc\u00ea pode encontrar problemas diferentes dos que eu encontrei, tente primeiro checar as issues do github, e se n\u00e3o estiver l\u00e1 n\u00e3o se acanhe e pergunte no f\u00f3rum. Se voc\u00ea \u00e9 um programador embeded experiente, ajude o pessoal l\u00e1 do Airbreak, vamos devolver para a comunidade. \ud83d\ude42<\/p>\n\n\n\n<p class=\"has-text-color has-vivid-red-color\"><strong>Como eu disse no come\u00e7o do post, isto \u00e9 uma prova de conceito, eu n\u00e3o endosso o seu uso em nenhum tratamento. Se voc\u00ea \u00e9 m\u00e9dico ou de um hospital ou institui\u00e7\u00e3o e deseja fazer testes cl\u00ednicos ficarei grato em ajudar.<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Este \u00e9 o tipo de ferramenta que a gente constr\u00f3i para nunca ter que usar.<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Abra\u00e7os,<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Ricardo Andere de Mello (gandhi) &#8211; <a href=\"mailto:quilombodigital@gmail.com\">quilombodigital@gmail.com<\/a><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>AVISO OBRIGAT\u00d3RIO Esta modifica\u00e7\u00e3o de equipamento \u00e9 um apenas uma prova de conceito, n\u00e3o deve ser utilizado para o tratamento de COVID ou qualquer outra doen\u00e7a respirat\u00f3ria. Seu uso n\u00e3o foi devidamente comprovado por&#46;&#46;&#46;<\/p>\n","protected":false},"author":1,"featured_media":114,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[10],"tags":[],"_links":{"self":[{"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/posts\/101"}],"collection":[{"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=101"}],"version-history":[{"count":24,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/posts\/101\/revisions"}],"predecessor-version":[{"id":134,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/posts\/101\/revisions\/134"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=\/wp\/v2\/media\/114"}],"wp:attachment":[{"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=101"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=101"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.quilombodigital.org\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}